Skip to Content

SENECA S.R.L.

K107A

RS485 / RS485 serial repeater, used to extend both the length or the number of devices admitted (Maximum 32) on the RS485 serial line. DIN rail mounting. Power supply: 19 ~ 30Vdc direct in conditioner or with K-BUS accessory
187.65

K107B

RS232 <--> RS485 serial converter, ideal for long-distance isolated transmissions. It has an X port: RS232 and a Y port: RS485. DIN rail mounting. Power supply: 19 ~ 30Vdc direct in conditioner or with K-BUS accessory
187.65

K107USB

RS485 <--> USB asyncronous serial converter, interface able to implement a RS485 serial port by using a PC USB port. Connect Modbus devices to PC by USB. DIN rail mounting. Power by USB port. Includes USB connection cable
187.65

K109LV

DC low voltage converter to mA or V. Input scales +/- 25mV to +/- 2000mV. Ideal for current shunts. 3-way galvanic isolation (Power supply, input and output). DIN rail mounting. Power supply 19 ~ 30 Vdc directly to terminals or through K-BUS accessory
187.65

K109PT

RTD to mA/V DC converter/isolator, with 2/3/4 wire PT100 resistance thermometer input and provides a mA/V output signal (0/4 to 20mA or 0 to 10V). Configurable output range. DIN rail mounting. Power supply 19 ~ 30Vdc or through K-BUS accessory
187.65

K109PT1000

RTD to mA/V DC converter, with PT100 input of 2/3/4 wires and provides a mA / V output signal (0/4 to 20mA or 0 to 10V). Configurable output range. DIN rail mounting. Power supply 19 ~ 30Vdc directly to terminals or through K-BUS accessory
187.65

K109PT-HPC

High performance converter from RTD to mA/V DC, with PT100 input of 2/3/4 wires and provides a mA / V output signal (0/4 to 20mA or 0 to 10V). Configurable output range. DIN rail mounting. Power supply 19 ~ 30Vdc or through K-BUS accessory
187.65

K109S

DC current/voltage to DC current/voltage isolator/converter. Input from 0/4 to 20mA or 0 to 10V and output 0/4 to 20mA or 0 to 10V. Configurable I/O range. DIN rail mounting. Power supply 19~30Vdc directly to terminals or through K-BUS accessory
187.65

Z-PC-DINAL2-52.5

DIN rail bus system head terminal + 3 slot 17.5 mm
187.65

K109TC

Thermocouple to mA / V converter, with thermocouple input type B, E, J, K, R, S, T, N and provides a mA / V output signal (0/4 to 20mA or 0 to 10V). Configurable output range. DIN rail mounting. Power supply 19 ~ 30Vdc or through K-BUS accessory
187.65

K109UI

Analog voltage/current converter with 0-10Vdc/4-20mA input and output, 1.5 kVac galvanic isolation, 3-way, DIN rail mounting, 24 Vdc power supply, optional K-BUS connectivity
187.65

K111

Amplifier/Converter with a pulse input (Contact IEC 1131.1 tipo 1, Namur, PNP/NPN, reed, photocell) and 2 outputs (PNP, BJT, Mosfet) of 60 mA/24Vdc. Max frequency: 20KHz. DIN rail mounting. Power supply 19 ~ 30Vdc or through K-BUS accessory
187.65

K112

Universal digital conditioner / isolator, one pulse input (Contact IEC 1131.1, Namur, PNP / NPN, reed, photocell) and 2 simultaneous outputs (NPN, PNP) of 30Vdc. Max frequency: 400Hz. DIN rail mounting. Feeding from 19 ~ 30Vdc or K-BUS accessory
187.65

K120RTD

RTD to mA DC converter/isolator, with 2/3/4 wire PT100/Ni100 resistance thermometer input and provides a mA output signal (4 to 20mA or 20 to 4mA). Configurable output range. DIN rail mounting. Power supply 5 ~ 30Vdc or through K-BUS accessory
187.65

K120RTD-C

Pt100 and Ni100 to 4..20mA (loop powered) converter - non isolated/ configured
187.65

S112M-23-ST

Power supply / amplifier for on/off sensors/ Power supply 24 Vac / dc
187.65

K121

Isolator / Converter with one input for (mA, mV, V, RTD, TCs, ohms) and convert it to an output signal from 4 to 20mA. Galvanic isolation of 3 ways. DIN rail mounting. Feeding from 7 to 30Vdc or with K-BUS accessory
187.65

POZZ-150

Welding thermowell, with 1/2" male PT100
187.65